THIS STOVE MUST BE PROPERLY INSTALLED AND OPERATED IN ORDER TO PREVENT THE POSSIBILITY OF AHOUSE FIRE. PLEASE READ THIS ENTIRE OWNER’S MANUAL BEFORE I
Lighting Stove With Fastfire™Self-Igniter:1. Fill the hopper with recommended pellet fuel and plug stove into wall outlet.2. Push the Start button on
General Operating ConsiderationsProper Burn Characteristics:The flame in your stove should be bright yellow under normal operation. If the flame becom
Thermostat InstallationNOTE: ALWAYS DISCONNECT POWER BEFORE PERFORMING THETHERMOSTAT INSTALLATION.To Install A Wall Thermostat:1. Check the type of th
NOTE: STOVE WILL NEED TO BE SHUT OFF AND COOLED ENOUGH TO HANDLE BEFORE ROUTINE CLEANING IS PERFORMED.ALWAYS DISCONNECT POWER BEFORE DOING ANY ROUTINE
Stove InstallationStove Installation ChecklistCheck off each item as you go through your installation. As part of the installation process:It is stron
1. After removing the packaging from the stove, lift the hopper lid, and remove all pre-packaged items thatwere shipped in the hopper. Also open the s
Stove Installation AssemblyYour Whitfield Advantage May Be Installed As:● A freestanding unit with a pedestal placed on a noncombustible floor pad.● A
IT IS RECOMMENDED THAT ONLY AN AUTHORIZED DEALER INSTALLYOUR PELLET STOVE. THE FOLLOWING INSTALLATION GUIDELINESMUST BE FOLLOWED TO ENSURE CONFORMITY
Determining Equivalent Pipe LengthTo determine whether a 3”or 4” exhaust system is required for your installation, review the sample installation belo
Installing Your Freestanding Pellet StoveExhaustPortQuickDisconnectStraight “L-vent”PipeInlet-AirPortMetal FreshAir PipeLythermGasketWallThimble45˚Elb
When you purchased your Whitfield stove, you joined the ranks of thousands of concerned individuals whose answer to their home heating system reflects
Stove Dimensions25”25”12-1/2”5-3/8”Dimensions Plus or Minus 1/4”
Installation ConfigurationsStandard Horizontal Installations45oDegreeElbow12”Minimumfrom groundor other surfaces1”Minimum6”MinimumNON-COMBUSTIBLE Hear
Venting OptionsThe Advantage Plus may be connected to an existing flue or by installing listed type “L” vent pipe. If aliner is run all the way to th
Mobile Home InstallationMOBILE HOME EXHAUST VENT PIPE INSTALLATION GUIDELINESUse only listed type “L” pellet vent pipe. Pipe should extend at least 3
Installing Your Insert Pellet StoveVENTING INTO AN EXISTING CHIMNEYThe Advantage Insert may be installed ina masonry or factory built fireplace asshow
Built In Heater InstallationDO NOT BLOCKVENT OPENINGThe Advantage Insert may be frameddirectly into a wall. Below are two (2)examples of this. The exh
The following areas need to be inspected as part of routine maintenance:Door RopeGasket:The condition ofthe rope gasketaround the doorand windowsshoul
APPENDIX ATROUBLE-SHOOTINGPROBLEM CAUSE(S) SOLUTIONSFire burns with a lazyorange flame. Pellets buildup in the grate and the win-dow gets sooted up.Fi
APPENDIX ATROUBLE-SHOOTING (CONT’D…)PROBLEM CAUSE(S) SOLUTIONSPellets will not feed.Stove runs for 30 minutesthen shuts down.Blowers will not shut off
APPENDIX ATROUBLE-SHOOTING (CONT’D…)PROBLEM CAUSE(S) SOLUTIONSBlowers will not operatewhen the start switch isdepressed.There is soot or fly ash inthe
Safety PrecautionsSafety Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Installati
Contact your local Authorized Whitfield Dealer for more information.Trimmed in solid oak, Whitfieldhearth Pads are available in anarray of colors and
APPENDIX CSHROUD PANEL ACCESS28.50”(Sml)32.00”(Med)36.00”(Lrg)40.75”(Sml)44.00”(Med)48.00”(Lrg)22”Shrouds and magnetic shroudtrim are available inthre
APPENDIX DWARRANTYTHIS WARRANTY IS ISSUED BY PYRO INDUSTRIES, INC. (MANUFACTURER) AND EXTENDS ONLY TO THE ORIGINAL PURCHASER OF THIS PRODUCT.The Manuf
1 #17150009 Scraper Rod2 #11750400 Door Assembly (slate)3 #11750100 Door Assembly (black)4 #11750300 Door Assembly (brown)5 #11750500 Door Assem
Common to Freestand & Insert Stove PartsFreestand Stove Parts
For Replacement Parts Please consult your local Authorized Whitfield Dealer #11950068 Lid Supt. Kit (NOT SHOWN)57 #11950156 Accent Trim Kit 58 #7205
Insert Stove Parts
Whitfield Pellet Advantage Plus Owners Operation ManualPart Number 11720198 REV.© 1997 Pyro Industries, Inc.Printed 5/15/98
Stove InstallationStove Installation Check List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13Pre-Installation As
Detailed Safety PrecautionsFuel - With its advanced UltraGrate technology, the Whitfield Advantage Plus is designed and approved forthe burning of woo
Auger - Pellet fuel is fed to the burn grate by a screw auger. This auger is driven by a high torque motor.The auger is capable of doing serious harm
General InformationUsing the UltraGrate burn system, the Whitfield Advantage Plus has been designed to burn wood residuepellets with up to 3% ash cont
Stove Operating Controls● Start Switch — The push-button START switch activates the convection blowerand the combustion blower. If the exhaust does no
FREESTAND STOVE DAMPERThe “push-pull” damper rod is located on the lower left side of the Freestand model stove.The proper damper setting, to use as a